Newcon-optik LRB 6000CI User Manual

Browse online or download User Manual for Optical devices Newcon-optik LRB 6000CI. Newcon Optik LRB 6000CI User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Operation Manual
LRB 6000CI
LASER RANGE FINDER
BINOCULARS
105 Sparks Ave., Toronto, ON M2H 2S5, Canada
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - LRB 6000CI

Operation Manual LRB 6000CI LASER RANGE FINDER BINOCULARS 105 Sparks Ave., Toronto, ON M2H 2S5, Canada

Page 2

6 Fig. 3 Display 1 – Low battery indicator 2 – Reticle (either -¦- or ) 3 – Units of measurement 4 – Measurement result 5 – Gating indicator 6 –

Page 3 - IMPORTANT INFORMATION

7 3. DELIVERY SET Standard delivery set for LRB 6000CI includes: Qty LRB 6000CI Carrying case Neck strap User’s manual Warranty card Cleaning cloth

Page 4

8 4. SPECIFICATIONS Optics Magnification 7x Objective lens diameter 50 mm Exit pupil diameter 7.1 mm Field of view 5 Type of coating Fully multi-c

Page 5 - TABLE OF CONTENTS

9 Compass Measured azimuth range 6400 mils /360 Accuracy ±1 Inclinometer Measured elevation range ±60 Accuracy ±1 Height measuring Yes (Meters

Page 6 - 1. BRIEF DESCRIPTION

10 5. OPERATION INSTRUCTIONS Installing the battery  Open the battery compartment using a suitable tool, or a coin. Insert a 9V Lithium non-magneti

Page 7

11 Using the Device The LRB 6000CI operational procedures are design to allow the user to use most applicable options in the fastest time possible. T

Page 8 - 2. DEVICE APPEARANCE

12 Factors affecting measuring distance Though maximum measurement distance depends on target reflectivity, weather conditions and other conditions, f

Page 9

13 Target selection logic On its way towards the target the laser beam may be reflected from various objects, thus decreasing ranging accuracy. The s

Page 10

14 Scanning regime the unit repeatedly measures and displays results every second while A button is pressed. To activate Scanning regime press and ho

Page 11 - 3. DELIVERY SET

15  Std – allows the user to select single action measurements: o Distance only (d) o Compass Only (C) o Elevation Only (E) o Speed Only (S) o

Page 13

16 o AUtO – Last Target Measurement* o PLGr – Communication to PLGR GPS* o PC – Communication to PC* o Reticule – Change reticule from + (cross) t

Page 14 - 5. OPERATION INSTRUCTIONS

17 Active mode of measurement (Std) Correction parameter Condition S, Sd, d Distance Install unit at 1 meter1 from flat target2 C, E Azimuth and elev

Page 15

18 Compass calibration If the System was exposed to a strong magnetic field or was not in use for a long time, the compass accuracy may diminish. To

Page 16

19 Gating mode In this mode gating function is activated: here user can set the minimal distance to the target, any object closer than the gating dist

Page 17

20 Data Recall mode In Data Recall mode results of the last 10 measurements can be displayed. Measurement results are saved in on-board memory in set

Page 18

21 Computer interconnectivity The unit supports RS-232 interface. Physical connection is performed through connector with threaded coupling mechanism

Page 19

22 GPS interconnectivity LRB 6000CI can transmit the acquired data to a GPS receiver using DB15 connector and PLGR/DAGR protocol. An optional cable is

Page 20

23 6. BEST MEASURING TECHNIQUE Laser range finder measures distance by catching laser beam reflected from the target. Everything that improves reflect

Page 21

24 reflections from all objects closer than the gating distance will be ignored. This is especially effective when ranging in unfavourable atmospheric

Page 22

25 7. STORAGE AND MAINTENANCE The unit is a sophisticated precision optical instrument equipped with laser and electronics. Therefore, it should be

Page 23

iii IMPORTANT INFORMATION Read prior to activation You have just purchased a sophisticated electro-optical device that emits invisible laser radiatio

Page 24

26 8. TROUBLESHOOTING Ranging does not work. The display is transparent. Check the charge of the battery. Replace it if it is weak. Ranging does not

Page 25

27 9. WARRANTY NEWCON warrants this product against defects in material and workmanship for one year from the date of the original purchase. Longer w

Page 26

28 10. CUSTOMER SUPPORT Should you experience any difficulties with your NEWCON OPTIK product, consult the enclosed manual. If the problem remains

Page 27 - TECHNIQUE

29 11. QUALITY CERTIFICATE Serial number _____________________________ The unit indicated above has passed the quality inspection. Production dat

Page 30 - 8. TROUBLESHOOTING

NEWCON OPTIK Printed in Canada R1 – 2.11

Page 31 - 9. WARRANTY

iv  Caution - use of optical instruments such as binoculars, loupes, mirrors, lenses, etc. with this product increases eye hazard  Note: Avoid eye

Page 32 - CUSTOMER SUPPORT

TABLE OF CONTENTS 1. BRIEF DESCRIPTION... 2 2. DEVICE APPEARANCE ...

Page 33 - 11. QUALITY CERTIFICATE

2 CAREFULLY READ ALL THE INSTRUCTIONS PRIOR TO USE! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANTY AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTIO

Page 34

3 Key Features of the LRB 6000CI Laser Rangefinder Binoculars  Modern digital circuitry allows targeting through most types of glass  First, last

Page 35

4 2. DEVICE APPEARANCE 1 – Eyepieces 2 – Objective / receiving lens 3 – Objective / emitting lens 4 – Dioptric adjustment rings 5 – Mode button 6

Page 36 - Printed in Canada

5 1 – Eyepiece 9 – Interpupillary distance adjustment lever 10 – Model Identification label 11 – Identification and certification label (at the bo

Comments to this Manuals

No comments